Mitto Family of Scan Converters User Guide
www.ensembledesigns.com
Timing Menu
The Timing controls adjust the timing of the HD SDI or SD SDI and composite output of Mitto with
respect to the reference input. If you set all three of the timing controls (Vertical, Horizontal, Fine
Phase) to zero, then Mittos output will be in exact time with the reference.
If, for example, you need to have Mittos output be one line early with respect to the reference in order
to auto-time properly into a production switcher, set the Vertical Timing to -1.
• Vert Timing – Set the vertical timing in lines. Use the slider controls or arrows to select a value,
or enter a value directly into the number field.
• Hor Timing – Set the horizontal timing in clocks. Use the slider controls or arrows to select a
value, or enter a value directly into the number field.
• Fine Phase – Set the fine phase timing in nsecs to color time the composite output. Use the
slider controls or arrows to select a value, or enter a value directly into the number field.
Mitto Timing Menu